Table I.

Summary of the localization of Nup214 and Nup358 using FEISEM and TEM


Antibody

SEM

TEM

Sample size (n)
Mean distance of gold from center of NPC (nm)
SD
SE
Sample size (n)
Mean distance of gold from midplane of NE (nm)
SD
SE
anti-214 106 11 9.3 0.90 36 31 5.7 0.95 
anti-358F 229 39 10.3 0.68 50 57 10.9 1.54 
anti-358V
 
114
 
31
 
12.0
 
1.12
 
56
 
51
 
10.0
 
1.34
 

Antibody

SEM

TEM

Sample size (n)
Mean distance of gold from center of NPC (nm)
SD
SE
Sample size (n)
Mean distance of gold from midplane of NE (nm)
SD
SE
anti-214 106 11 9.3 0.90 36 31 5.7 0.95 
anti-358F 229 39 10.3 0.68 50 57 10.9 1.54 
anti-358V
 
114
 
31
 
12.0
 
1.12
 
56
 
51
 
10.0
 
1.34
 

The position of gold particles labelling CAN/Nup214 (anti-214) and RanBP2 (anti-358F and anti-358V) were determined in scanning EM and TEM.